beautypg.com

Parameters, Level table, How to display – Panasonic WJ-SX 150A User Manual

Page 88

background image

91

Parameters

• Operator Number

This box displays a list of registered operators.

1-6:

These are operator numbers who are registered as

the factory default setting. Operator Number 1 can-
not be deleted.

Timer:

This operator is used for the priority change of a

timer event. When the timer event's priority is higher
than that of an operator, the event is valid. When an
operator's priority is higher than that of a timer
event, the event is invalid. This operator cannot be
deleted.

• Add Operator Number

This drop-down menu is used for the new operator number
selection. 7 to 16 can be added.

• Operator Group

This group configures each operator's password, level and
priority.

ID:

Enter an operator's ID. From 1 to 99999 are avail-
able.

Password:

Enter a password. From 1 to 99999 are

available.

Level:

Select 1, 2 or 3. Refer to Level Table for details

on level setting.

Priority:

Select the operator's priority from 1 (highest)

to 16 (lowest).

• Camera Access Group

This group configures the camera operation coverage of
each operator.
Click on each camera's checkboxes and determine the
available operation.

1 (View & Control):

The operator can display the cam-

era image on the monitor and control panning/tilt-
ing.

2 (View Only):

The operator can display the camera

image on the monitor, but cannot control the pan-
ning/tilting.

3 (Prohibited):

The operator can neither display the

camera image on the monitor nor control the pan-
ning/tilting.

(Add) button

Adds a new operator to WJ-SX150A.

(Edit) button

The registered parameters become editable by clicking on
this button after selecting the operator number.

(Delete) button

Deletes an operator from WJ-SX150A after you select the
operator.

(OK) button

Saves the configuration and closes the Operator
Registration window.

Level Table

This window configures the restrict level of each operation.
The restrict level is classified in Level 1, 2, and 3.

How to Display

To display this window, click on the

(Level Table) but-

ton in the main window (p. 80).

Parameters

• Permission

Click on each checkbox to classify the following operations
by three levels.

SX150A Setup:

Setting up this matrix switcher system

Camera Setup:

Setting up the cameras

Program Preset Position:

Registering a camera's pre-

set position

Camera Control:

Controlling a camera

Camera Selection:

Selecting a camera

Recorder Setup:

Displaying the recorder's setup menu

Recorder Control:

Controlling the recorder

All Alarm Reset:

Resetting all the alarms

Single Alarm Reset:

Resetting an alarm

Alarm Suspend:

Suspending an alarm

Call Sequence:

Activating a tour or group sequence

Alarm History Display:

Displaying the alarm history

Video Loss History Display:

Displaying the video loss

history

System Status Display:

Displaying the system status

OSD Control:

Controlling on-screen display (Time and

date, monitor status, camera title, and event)

(Save Exit) button:

Saves the configuration and closes the Level Table window.

(EXIT) button

Cancels the configuration and closes the Level Table win-
dow.