beautypg.com

To control a recorder via the network – Panasonic WJ-SX 150A User Manual

Page 42

background image

44

To Control a Recorder via the Network

The following is the description of the connection between a recorder and this unit to control the recorder via the network.

1. Set the recorder's unit address to a number 5 or larger . (Refer to the recorder's operating instructions.)
2. Connect the unit’s CAM OUT 1 to 8 connectors to the recorder’s VIDEO IN 1 to 8 connectors with a coaxial cable.
3. Connect the unit’s EXT IN connector to the recorder’s MULTI SCREEN OUT connector with a coaxial cable.
4. Connect the unit’s DATA HDR and DATA4 connectors to the recorder’s DATA port with a daisy chain connection cable kit

(WV-CA48/10K).

5. Select the recorder’s new unit address, which is set in Step 1, in 600 RECORDER (refer to p. 71 ) of SETUP MENU or the

Recorder (refer to p. 97) window of WJ-SX150A Administrator Console.

6. Through a browser or the recorder’s SETUP MENU, set the CTL-UNIT ADDR to a number other than 1. (Refer to the

recorder’s operating instructions.)

Notes:

• Select the PS·Data protocol for the DATA 4 setting. (Refer to p. 74 CAMERA/DATA1 – 4 PORT or p. 96 Data Port.) If the ter-

minal mode is selected, you cannot control the recorder.

• The recorder will not be operable if its unit address is set to 1/2/3/4.
• If the recorder's unit address in Step 1 and the recorder setting in Step 5 are different, the recorder will not be operable.
• In these connections, you cannot use a PS·Data system controller.
• If you use two WJ-HD200 Series recorders, you cannot control the recorders with the system controller connected to the

Master unit. When recording the images from CAM IN 1 to 16, it is recommended to use WJ-HD500 Series recorders.

SIGNAL GND

POWER

AC IN

CAMERA

1

1

2

2

3

3

2

DATA 3 DATA 2

SERIAL

ALARM

TERM

OFF

ON

4

2

1

4

3

CAMERA

SW IN

RS485(CAMERA)

LINE

SELECT

MONITOR OUT

EXT IN

(PLAY IN)

EXT OUT

(REC OUT)

OUT

IN

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

16

16

RS485(CAMERA)

DATA 4

DATA HDR

PS•DATA

DATA 1

SIGNAL GND

POWER

DATA

10/100BASE-T

MODE

RS-232C

MULTI

SCREEN OUT

SPOT

OUT

1

1

ALARM/REMOTE

OFF

ON

2

2

3

3

4

4

5

5

6

6

7

7

8

8

OUT

VIDEO

OUT

AUDIO

IN

IN

LAN *

* LAN: Local Area Network

VIDEO IN

1 to 8

CAMERA

OUT 1 to 8

(WV-CA48/10K)

Recorder

Matrix Switcher

DATA HDR

DATA 4

(PS

DATA)

MONITOR OUT

EXT IN

Monitor

MULTI
SCREEN OUT

DATA

LAN Cable

HUB/Router