161

Error Code List

Error code(ASCII)

Error type

Meaning

ER000

No error

There is no error.

ER001

No associated command

There is no associated command.

ER002

Parameter invalid

The parameter's number, digit and range are invalid.

ER003

Receiver buffer's overflow

The receiver buffer has reached overflow capacity.

ER301

Command invalid

Invalid operation mode caused the command error.

ER302

Parameter invalid

The parameter's number, digit and range are valid, but the operation mode

is invalid.

ER303

Gateway reception overflow

Reception buffer overflow has occurred on the other device during the

gateway communication.

ER305

Gateway timeout error

Timeout error has occurred during the gateway communication.

ER309

Internal error

The internal processing error has happened.

Example: The command is valid but it cannot be executed.

(1) The unit receives the zoom command while selecting a camera without electronic zoom function.

Transmission Command (ASCII)

[STX] CMD:R01ZM [ETX]

Transmission Command (ASCII)

[STX] ANS:R01ZM:ER301 [ETX]