beautypg.com

Matrix switcher recorder – Panasonic WJ-SX 150A User Manual

Page 39

background image

41

To Record the Camera Images in Maximum
Recording Rate

The following is the description of the connection between a
recorder and this unit for the maximum-rate recording.

1. Set the unit address of the recorder to 1. Then, set the

recorder’s CAMERA GENLOCK to ON in its SETUP
MENU. (Refer to the recorder's operating instructions.)

2. Connect the unit’s CAM OUT 1 to 16 connectors to the

recorder’s VIDEO IN 1 to 16 connectors with a coaxial
cable.

3. Connect the unit’s EXT IN connector to the recorder’s

GENLOCK OUT connector with a coaxial cable.

4. Connect the unit’s DATA HDR connector to the

recorder’s DATA port with a modular cable.
(The control data and alarm signal will be output from
the unit to the recorder.)

5. After the connection, set the unit’s EXT IN to GENLOCK

ON through SETUP MENU or WJ-SX150A Administrator
Console (Refer to pp. 71 or 97).

Notes:

• You need WJ-HD500A or a newer model for the maxi-

mum-rate recording.

• The playback, multiscreen output or live images from the

recorder are not displayed on Monitor 1 to 4. To confirm
the images, you need to connect another monitor with
the recorder.

• The recorder will not operate if its unit address is set to

other than 1.

• Make sure the recorder’s unit address is set to 1

through SETUP MENU or WJ-SX150A Administrator
Console. (Refer to pp. 71 or 97.) If another number is
selected, you cannot control the recorder.

Matrix Switcher

Recorder

16

16

15

15

14

14

13

13

12

12

11

11

10

10

9

9

8

8

7

7

6

6

5

5

4

4

3

2

2

3

1

1

SIGNAL GND

10/100

BASE-T

SPOT

OUT

IN

EXT STORAGE

COPY

CONTROL

ALARM

VIDEO

MODE

DATA

REMOTE(WV-CU50)

GEN-LOCK OUT

SERIAL

IN

OUT

OUT

MULTI SCREEN OUT

AUDIO

EXT IN

GENLOCK
OUT

MULTI
SCREEN
OUT

DATA

DATA HDR

Monitor

CAMERA

1

1

2

2

3

3

2

DATA 3 DATA 2

SERIAL

ALARM

TERM

OFF

ON

4

2

1

4

3

EXT OUT

(REC OUT)

CAMERA

SW IN

RS485(CAMERA)

LINE

SELECT

MONITOR OUT

EXT IN

(PLAY IN)

OUT

IN

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

16

16

RS485(CAMERA)

PS•DATA

DATA 4

DATA HDR

DATA 1

• Make sure the recorder’s unit address is set to 1

through SETUP MENU or WJ-SX150A Administrator
Console. (Refer to pp. 71 or 97.) If another number is
selected, you cannot control the recorder.