beautypg.com

Panasonic LK-T Relays User Manual

Lk-t relays, Lk-t, Specifications

background image

LK-T

1

ds_61113_0004_en_lkt: 091008J

SPECIFICATIONS

SLIM POWER RELAY

WITH HIGH INRUSH

CURRENT CAPABILITY

TV-8 CERTIFIED

LK-T RELAYS

FEATURES

1. High inrush current capability
1) Operating load capability:
inrush 118 A, steady 8 A
2) UL/C-UL TV-8 approved
2. High insulation resistance
1) Creepage distance and clearances
between contact and coil: Min. 6 mm

.236

inch

(In compliance with IEC65)

2) Surge withstand voltage between
contact and coil: 10,000 V or more

3. High noise immunity realized by the
card separation structure between
contact and coil
4. Conforms to the various safety
standards
UL, C-UL, TÜV, and SEMKO approved

25.0

24.0

11.0

.984

.945

.433

Contact

Coil

#1 This value can change due to the switching frequency, environmental conditions,

and desired reliability level, therefore it is recommended to check this with the
actual load.

Remarks

*

1

Measurement at same location as “Initial breakdown voltage” section.

*

2

Detection current: 10mA

*

3

Wave is standard shock voltage of

±1.2 × 50μs according to JEC-212-1981

*

4

Excluding contact bounce time.

*

5

Half-wave pulse of sine wave: 11 ms; detection time: 10

μs

*

6

Half-wave pulse of sine wave: 6 ms

*

7

Detection time: 10

μs

*

8

The upper operation ambient temperature limit is the maximum temperature that
can satisfy the coil temperature rise value. Refer to 1. Usage, transport and
storage conditions in NOTES on page 3.

Characteristics

Arrangement

1 Form A

Initial contact resistance
(By voltage drop 6 V DC 1 A)

Max. 100 m

Ω

Contact material

AgSnO

2

type

Rating
(resistive load)

Nominal switching
capacity

5 A 277 V AC

Max. switching power

1,385 V A

Max. switching voltage

277 V AC

Max. switching current

8 A (120V AC)

Min. switching capacity

#1

(Reference value)

100 mA, 5 V DC

Expected life
(min. operations)

Mechanical (at 180 cpm)

10

6

Electrical (at 20 cpm)
(at rated load)

10

5

Nominal operating power

250 mW

Max. operating speed

20 cpm (at rated load)

Initial insulation resistance*

1

Min. 1,000 M

Ω (at 500 V DC)

Initial *

2

breakdown
voltage

Between open
contacts

1,000 Vrms for 1 min.

Between contact
and coil

4,000 Vrms for 1 min.

Initial surge voltage between contact
and coil*

3

10,000 V

Operate time*

4

(at nominal voltage)

Max. 15ms (at 20

°C

68

°F

)

Release time (without diode)*

4

(at nominal voltage)

Max. 5ms (at 20

°C

68

°F

)

Temperature rise (at 70

°C)

Max. 35

°C with nominal coil

voltage and at 5 A contact

carrying current

(resistance method)

Shock
resistance

Functional*

5

200 m/s

2

{approx. 20 G}

Destructive*

6

1,000 m/s

2

{approx. 100 G}

Vibration
resistance

Functional*

7

10 to 55Hz

at double amplitude of 1.5mm

Destructive

10 to 55Hz

at double amplitude of 1.5mm

Conditions for operation,
transport and storage*

8

(Not freezing and
condensing at low
temperature)

Ambient
temp.

–40

°C to +70°C

–40

°F to +158°F

Humidity

5 to 85% R.H.

Air
pressure

86 to 106 kPa

Unit weight

Approx. 12 g

.42 oz

TYPICAL
APPLICATIONS

• Audio visual equipment
• Flat TVs and audio equipment, etc.
• Office equipment
• Home appliances

ORDERING INFORMATION

Contact arrangement

Protective construction

Coil voltage(DC)

1a: 1 Form A

F: Flux-resistant type

5, 9, 12, 24V

Ex. LKT

1a

F

12V

UL/C-UL, TÜV, SEMKO, TV-8 approved type is standard.
Notes: 1. Standard packing Carton: 100 pcs. Case: 500 pcs.