beautypg.com

Running sequence, Tour sequence, Group sequence – Panasonic WJ-SX 150A User Manual

Page 182

background image

10

Note: This section describes the terminal mode. To operate

in the PS·Data mode, refer to the operating instructions.

Tour Sequence

The following functions are available if a tour sequence has
been previously configured through SETUP MENU or WJ-
SX150A Administrator Console. Any tour sequence can be
assigned to any monitors.

1. Select the desired monitor and camera. (Refer to p. 3

Monitor Selection and p. 3 Camera Selection.)

2. To select the desired tour sequence number, press the

numeric buttons.

3. When you have selected a wrong number, press the

CLEAR button to clear the numeric input.

4. Press the TOUR SEQ/GROUP SEQ button to run the

tour sequence in the forward direction on the active
monitor.

5. Press the SEQ PAUSE/SEQ STOP button to pause a

tour sequence on the active monitor.
The "P" sign (indicating the pause status) is displayed
at the tour sequence number on the active monitor, and
a camera number currently selected appears on the
LCD.

• Press the SEQ PAUSE/SEQ STOP button to restart a

tour sequence forward from the next step that was pre-
viously paused.

• Press the + button to move the sequence one frame to

the next step from the step that was previously paused.

• Press the – button to move the sequence one frame to

the previous step from the step that was previously
paused.

6. Press the SEQ PAUSE/SEQ STOP button while holding

down the SHIFT button to stop a tour sequence on the
active monitor and return to spot monitoring.

Group Sequence

The following function is available only if a group sequence
has been previously established in WJ-SX150A
Administrator Console.
As described earlier, a group sequence determines the
assignment of monitors and cameras. Therefore, monitor
selection is not required.

1. Press the numeric buttons to select a desired group

sequence number.

2. When you have selected a wrong number, press the

CLEAR button to clear the numeric input.

3. Press the TOUR SEQ/GROUP SEQ button while holding

down the SHIFT button to run a group sequence for-
ward on the assigned monitors.

4. Press the SEQ PAUSE/SEQ STOP, + or – button to

operate the group sequence. Refer to Step 5 of Tour
Sequence in this page for how to use these buttons.

5. To stop the sequence, select one of the monitors that

are being run on the selected group sequence, then
press the SEQ PAUSE/SEQ STOP button while holding
down the SHIFT button

Note: If an alarm is activated during a sequence pause, the

sequence runs again after the matrix switcher recovers
from the alarm mode.

RUNNING SEQUENCE

Mon1 Cam01

T04

Mon1 Cam07

T04P

Mon1 Cam01

T01