61

SETUP PROCEDURES

Setup Procedures

This unit has two setting procedures.
The one is SETUP MENU, which is the unit's on-screen dis-
play (OSD).
The other is WJ-SX150A Administrator Console, which
operates on the PC.

• SETUP MENU (OSD)

The basic functions, which are essential for the operation,
are configurable. However, some items are not config-
urable. The settings about group sequences, operators and
schedules, etc.

• WJ-SX150A Administrator Console (PC)

All the functions of this unit (except camera manual clean-
ing) are configurable. You need a PC to use WJ-SX150A
Administrator Console.
Refer to p. 79 WJ-SX150A ADMINISTRATOR CONSOLE for
details on the platform and installation.

Notes:

• The Master unit administrates all the system settings.

Do the setup procedure with the Master unit only.

• To use WJ-SX150A Administrator Console, you need to

prepare a PC and a 9-pin D-sub cable.(Refer to p. 48.)

• When changing the configuration of WJ-SX150A

Administrator Console, configuration data getting and
putting are necessary between the unit and PC to acti-
vate your configuration.

Description of Setup Procedures

This chapter describes about configurable items.

Master-Slave Connection Settings

Both SETUP MENU and WJ-SX150 Administrator console
can configure the parameters of master-slave connection
and logical camera number.

• Master-slave: The composition of the master-slave con-

nection is configurable.

• Logical camera number: Logical camera number,

which is used for camera control and monitor display,
can be assigned to each camera.

Sequence Settings

SETUP MENU can configure tour sequences. WJ-SX150A
Administrator Console can configure both of tour
sequences and group sequences.

• Tour sequence: Up to 32 tour sequences are config-

urable (64 steps per tour).

• Group sequence: Tour sequences can be activated on

up to 4 monitors simultaneously (1 tour sequence per
monitor).

Schedule Settings

SETUP MENU can configure daylight saving time. WJ-
SX150A Administrator Console can configure timer event,
camera cleaning, and daylight saving time.

• Timer event: A sequence or spot mode can be activat-

ed on the regular time of every month, week or day.
Up to 50 timer events can be registered.

• Camera cleaning: Camera cleaning can be executed

on the regular time of every month, week or day.

• Daylight saving time: Daylight saving time schedule for

20 years are configurable.

SETUP MENU (OSD)

Master-slave connection settings
• Master-slave
• Logical camera number

Sequence settings
• Tour sequence
• Group sequence

Schedule settings
• Timer event
• Camera cleaning
• Daylight saving time

Alarm settings
• Alarm mode
• Alarm event
• Alarm input/Alarm port

Operator settings
• Operator registration
• Level table
• Monitor select (Monitor selection)
• Auto login/logout (Auto log-in/log-out)

System settings
• Clock (Time and date) *

1

• Cable compensation
• Camera title
• Data port *

2

• Recorder
• Multiplexer
• Mux camera (Multiplexer) title

Setup file operation
• Put a file to SX150A
• Get a configuration data from SX150A

SX150A Admin Console configuration
• File open
• Account manager
• Communication (Serial) port

• Camera manual cleaning ON/OFF

WJ-SX150A Administrator Console (PC)

*

1

WJ-SX150A Administrator Console can configure the

display pattern.

*

2

WJ-SX150A Administrator Console can configure the

communication speed (baud rate) of the ports Data 1 to 4.