Configuration of the Update Server 193

KIRK Wireless Server 600v3 Installation and Configuration Guide

The times command will check the current time against . If it does not match this

restriction, any further processing of the command file is cancelled. is a comma

separated list of hours. Only those hours listed are considered valid times for execution

of the command file.

mod cmd UP1 times /allow 12,22,23,0,1,2,3,4

will allow command executions only between 12:00 and 12:59 and 23:00 and 4:59 local

time (on a 24h clock). Note that if the device has no time set (yet), all command

executions will be cancelled.

If the /initial parameter is set, then no commands will be executed within the first

minutes after the device has been booted. This is done to avoid firmware

download and flashing when installing devices.

mod cmd UP1 times /allow 12,22,23,0,1,2,3,4 /initial 6

will suppress any command file processing within the first six minutes after each boot of

the device. If /initial is set, for new devices (or those that have been reset to factory

settings), the command file will be retrieved even if it normally would be suppressed by

the /allow parameter. This allows new devices to retrieve a site specific standard

configuration quickly.

13.5.3 Prot Command

To initiate a firmware update, the following command can be executed:

mod cmd UP0 prot

This command downloads new firmware (if available) from the specified URL onto the

device. Finally, the is executed.

KIRK devices have an internal variable that is initially empty (or empty if the device was

reset with the standard settings) called UPDATE/PROT. The prot command compares

the content of with the UPDATE/PROT variable. If both match, no

firmware is downloaded. If the UPDATE/PROT variable is not set (new devices or after a

device restart), the content of is compared with the built number of the

current firmware. Once the firmware has been successfully downloaded, the UPDATE/

PROT variable is overwritten with the content of . Note that the

parameter is not compared with the firmware version currently loaded. It

is the responsibility of the administrator to keep this standard.

If the parameter ends with a slash (‘/’), a standard firmware file name is appended

to the URL depending on the product description (for example, IP1200.bin for an IP

DECT system).

mod cmd UP0 prot http://192.168.0.10/firm/ip1200.bin ireset 04-5656