beautypg.com

Printronix ThermaLine Series User Manual

Page 96

background image

Commands

4–52

FC

The optional form count parameter specifies the

number of copies of the form to print. Enter the

appropriate number.

When the last page prints, the IGP/PGL returns to the

Normal mode automatically. Do not use the form count

parameter if dynamic data (AFn and BFn parameters),

incremental data (ICNT or IRST parameters), overlay

data, or EVFU data are used in the Execute command.

ICNTn

The optional incremental form count. Enter ICNT and

the Incremental value as described in the Execute

Incremental Dynamic Data command described on

page 4–56.

IRSTn

The optional incremental reset count parameter. Enter

IRST and the reset value as described in the Execute

Incremental Dynamic Data command described on

page 4–56.

AFn;(D)ASCII text(D)

The Execute Dynamic Alphanumeric Data command.

Enter the dynamic alphanumeric data during the

Execute Form mode as described in “Execute Form:

Dynamic Alphanumeric Data” on page 4–54.

BFn ;(D)data(D)

The Execute Dynamic Bar Code Data command. Enter

the dynamic bar code data during the Execute Form

mode as described in “Execute Form: Dynamic Bar

Code Data” on page 4–55.

(cc)IAFn;[idir] STEPMASK;[RPTn;] [RSTn;] (D)STARTDATA(D)

The Execute Incremental Dynamic Alphanumeric Data

command. Supply the data as described on page 4–57.

(cc)IBFn; [idir] STEPMASK; [RPTn;] [RSTn;](D)STARTDATA(D)

The Execute Incremental Dynamic Bar Code Data

command. Supply the data as described on page 4–57.