Printronix ThermaLine Series User Manual
Page 204
Bar Codes
5–66
EAN 13 Command Format
BARCODE
EAN13 [+n]; [VSCAN;] [SCB;] [MAG;] [Hn[.m];] [BFn;] [DARK;] SR;
SC
[(D)data field(D)]
[PDF [;LOC] [;FONT]]
STOP
BARCODE
The Bar Code command; enter BARCODE.
EAN13
Designates bar code type EAN 13; enter EAN13.
+n
Optional parameter to provide a 2– or 5–digit add–on
code at the end of the bar code data field. Enter a plus
sign (+) and a value of 2 or 5. The first bar of the
add–on code is separated by nine modules from the last
bar of the EAN symbol and a left guard pattern. No
center or right guard pattern exists.
VSCAN
Optional parameter to orient the bar code structure
vertically. To select a vertical bar code, enter VSCAN.
If VSCAN is not entered, the bar code is oriented
horizontally.
SCB
This option shortens the length of the center guard
bars, which are normally full length.
MAG
Optional parameter to magnify (horizontally expand)
the bar code symbol. The magnification default value
is X1. Increasing the magnification adjusts printed
character density.
You can also use XR or XRD as defined on page 5–4.
(You must specify 8 digits for MAG for variable ratio.)