Commands

4–4

There is a configuration option that determines whether any data preceding a

command is printed or ignored.

All PGL commands begin with the Special Function Control Character

(SFCC). When the command is not followed by a valid line terminator, it

must also end with the SFCC. Any illegal command or non–terminated

command will print as text.

These features, when used in combination with the new dynamic data rule,

are useful for those whose systems count the number of lines printed and

automatically issue a form feed. Now, the line count can be maintained by

combining overlay data and commands in a single print line. For example:

Normal text ~FONT;BOLD ON~Bold text~FONT;BOLD OFF;SLANT

1~Slanted text~EXPAND;2:2~~FONT;SLANT 0~ Enlarged upright text

would yield:

Normal text Bold text Slanted text

Enlarged

Upright Text

Line Terminator

Each command line must be terminated by a line feed (or a carriage return

with a line feed), or a paper motion command. When an inline command is

not followed by a valid line terminator, it must also end with the SFCC. The

command line will not be accepted if not properly terminated. Refer to your

system operator’s manual for your system keyboard and your printer

configuration codes to determine which key(s) (such as ENTER, LINE

FEED, RETURN, etc.) perform a line feed, carriage return with line feed, or

form feed function.

Printable Character

To print, alphanumeric and bar code data must be enclosed by a printable

character (a delimiter). This delimiter is represented by (D) in the command

format. In this manual, an asterisk (*) is used in most examples as the

printable character. (The parentheses are not entered.) Any printable

character can be used as this delimiter except a slash (/) or the SFCC.