Alphanumerics, incremental: fixed data fields – Printronix ThermaLine Series User Manual
Page 66
Commands
4–22
Alphanumerics, Incremental: Fixed Data Fields
Purpose
To automatically increment/decrement fixed alphanumeric data fields.
Mode
CREATE
NOTE:
In the command format below, incremental alphanumeric command
parameters are shown in boldface type; standard alphanumeric command
parameters and optional nonincremental parameters are shown in italics.
Due to space constraints, the command parameters are separated into two
lines. During actual IGP/PGL input, DO NOT separate command
parameters.
Format
ALPHA
[R;] [E;] [Cn;] I; [DIR;] [UC;] SR; SC; VE; HE;[idir] STEPMASK;
[RPTn;] [RSTn;] (D)STARTDATA(D)
STOP
I
Identifies this alphanumeric command as an
Incremental Alphanumeric command; enter I.
idir
The optional increment direction parameter to specify
an increment (add) or decrement (subtract) to the data.
Enter a plus sign (+) or leave the field blank to
increment (the default). Enter a minus sign (–) to
decrement.
STEPMASK
Defines the increment amount (step), the number of
character positions in the data field, and provides a
mask to control the increment function on specific
parts of the data. Enter STEPMASK, and enter the
appropriate value. Refer to Table 4–1 on page 4–19 for
complete information on STEPMASK parameter
values.
RPTn
The optional incremental repeat count parameter to
specify the number of times a particular field value is
repeated before it is incremented. A repeated field
value is useful when printing multiple rows/columns of
identical labels before increasing to the next value.