Printronix ThermaLine Series User Manual
Page 107
4–63
Commands
All Font command parameters are reset to default values upon receiving a
NORMAL, RESET, CONFIG;RESET, or new CREATE command.
Multiple font commands within a single form will save the last font
command parameters specified. Symbol sets can also be selected using the
ISET or USET commands. (Refer to the “Multinational Character Sets”
chapter.)
Fonts in the HP LaserJet II format may also be downloaded to the printer.
They may be downloaded into either the SRAM or FLASH memory
modules, and then will be available permanently (at least as long as the
FLASH or SRAM module is installed). Note that these fonts are
proportional fonts. They may be selected using the FONT command;
however, the POINT size, BOLD, ITALIC and SYMSET parameters are
ignored.
Use the PTX_SETUP command to download a font. Refer to Chapter 3 in
this manual for details.
The downloaded fonts are selected in the same manner as are the other
expansion fonts, i.e., with the FONT command. The font number given in
the download command will be the same number used in the FONT
command to select it.
Example
The following command selects the Letter Gothic font (#93779) with a
right slant. This font will continue to print until another Font command, a
Normal mode command, or a Reset command is entered.
~FONT;FACE 93779