beautypg.com

Printronix ThermaLine Series User Manual

Page 59

background image

4–15

Commands

HE

Defines the horizontal expansion factor to enlarge

characters horizontally. Enter a value between 0 and

139. Zero specifies the standard font (no expansion).

An HE value must be entered. Elongated (E) and

compressed (Cn) characters cannot be used with a

horizontal expansion other than zero.

(D)

The printable character (quotation marks for example)

identifying the start and finish of the alphanumeric

string. Enter any printable character other than a slash

(/), the SFCC, or a character used within the

alphanumeric string itself. You must use the same

character at both ends of the alphanumeric string, but it

will not print with the data.

text

The group of ASCII characters (the alphanumeric

string) to print. Enter any of the standard ASCII

printable characters (except the character used to

delimit the string in the D parameter). The data appears

as “prepositioned” information on the form beginning

at the location specified by SR and SC. This is the

“fixed” or static alphanumeric data; once defined on

the form, it is changed only by redefining the form

using the Alphanumerics command.

STOP

Stop indicates the end of the Alphanumeric command;

enter STOP, and the IGP/PGL will wait for a new

command. If not entered, the IGP/PGL will wait for

another set of Alphanumeric command parameters.

Comments

As dynamic data, the location of the alphanumeric field is established in the

Create Form mode and the actual alphanumeric data is continuously

redefined before placement on the form in the Execute Form mode. You

can also rotate and reverse print the alphanumeric string using this

command.

Example

The following program and example in Figure 4–3 illustrates the

Alphanumeric command capabilities. To illustrate positioning, starting row

and column are indicated on the example but do not necessarily reflect

actual location on the page.