Vertical line errors – Printronix ThermaLine Series User Manual
Page 336
Error Codes
8–4
Vertical Line Errors
10
VERTical line starting column SC out of bounds
The column specified by the second parameter in the vertical line command
places the vertical line outside the form boundaries.
11
VERTical line starting row SR out of bounds
The upper (starting) row of the vertical line specified by the third parameter
in the vertical line command places the vertical line outside the boundaries of
the form.
12
VERTical line ending row ER out of bounds
The lower (ending) row of the vertical line specified by the fourth parameter
in the vertical line command places the vertical line outside the boundaries of
the form.
13
VERTical line format or delimiter error
Some type of format or delimiter error was detected in the parameters of the
vertical line command. This error is usually caused by one or more of the
following:
a. A missing semicolon;
b. A colon in place of a semicolon;
c. Too many or too few parameters in the command string;
d. Alpha characters instead of numeric characters in the parameters.
14
Insufficient memory to store the VERTical line
No more room in the IGP/PGL memory exists for another vertical line. The
rest of the vertical line commands are flushed until the Stop command is
found. Processing will then continue normally. To create space in the
IGP/PGL memory, delete forms with vertical line elements that are no longer
required.
15
VERTical line starting row SR > ending row ER
The upper (starting) row parameter of the vertical line command is greater
than or equal to the lower (ending) row parameter.
16
VERTical line thickness LT error
The thickness of the vertical line specified by the first parameter in the
vertical line command is incorrect. This error is usually caused by specifying
a thickness of zero.
17–19
Not defined.