beautypg.com

Multinational character set errors – Printronix ThermaLine Series User Manual

Page 355

background image

8–23

Error Codes

Multinational Character Set Errors

150

ISET character selection parameter n error – 00 to 31

An ISET character set selection parameter value between 0 and 31 was

expected. Error was caused possibly by an invalid numeric value or an alpha

character.

151

USET decimal input error in input parameter

The USET command was expecting a decimal parameter and either received

none or received an alpha character.

152

USET character set n parameter error

A USET character set selection parameter value between 1 and 8 was

expected. Error was caused possibly by an invalid numeric value or an alpha

character.

153

USET substituted character illegal – must be 1 of 16

During character substitution in the USET command, the hex value for the

character being replaced must be one of the specified 16 hex values. Only the

following hex values (Ca) can be replaced by another hex value (Fa): 21, 22,

23, 24, 25, 26, 40, 5B, 5C, 5D, 5E, 60, 7B, 7C, 7D, 7E.

154

USET defined character illegal – must be hex 20–FF

During the USET command, the hex value for the substituted character (Fa)

must range between 20 and FF hex. The value given may be out of bounds.

155

USET syntax error – END command is expected

An END command is expected when the USET character set definition is

completed.

156

No such CONFIGuration option

157

Left or Top/Bottom margin too large for the current page size.

158–159 Not defined.