Commands

Supplying Dynamic Data for Incremental Fields

Incremental dynamic data fields are created in the Create Form mode using

the incremental alphanumeric or bar code commands. The incremental

dynamic data itself is supplied during the Execute Form mode at the top of

the form prior to any overlay data. The incremental dynamic data (either

alphanumeric or bar code data) can be changed with each new batch of

forms. Incremental dynamic data fields specified in the Create Form mode

will not appear on the form if corresponding incremental dynamic data is not

supplied in the Execute Form mode.

Format

For incremental dynamic alphanumeric data:

(cc)IAFn; [idir] STEPMASK; [RPTn;] [RSTn;] (D)STARTDATA(D)

For incremental dynamic bar code data:

(cc)IBFn; [idir] STEPMASK; [RPTn;] [RSTn;] (D)STARTDATA(D)

(cc)

The Special Function Control Character.

IAF

Identifies the command as incremental alphanumeric

dynamic data; enter IAF.

IBF

Identifies the command as incremental bar code

dynamic data; enter IBF.

n

Identifies the field number of the dynamic data field as

entered in the Create Form mode. Replace n with the

number used to identify the field when it was defined.

idir

The optional increment direction parameter to specify

an increase or decrease of the data. Enter a plus sign

(+) or leave the field blank to increment (the default).

Enter a minus sign () to decrement.

STEPMASK

Defines the increment amount (step), the number of

character positions in the data field, and provides a

mask to control the increment function on specific

parts of the data. Refer to “Incremental Bar Code

Fields” on page 5–116 or “Alphanumerics, Incremental

Fields” on page 4–18 for complete information on

STEPMASK parameter values.