Error Codes

8–10

Logo Errors

50

LOGO horizontal width HL > 240 or dot row > HL

a.

The horizontal width of the logo is equal to zero or greater than 240.

The IGP/PGL automatically reverts to Normal mode when this occurs.

b. A dot position specified in the logo program exceeds the specified

horizontal width of the logo. When this occurs, the buffer is flushed

until a line terminator is found, and then logo construction continues

normally.

51

LOGO vertical length VL > 252 or dot row n > VL

a.

The vertical length of the logo is equal to zero or greater than 252. The

IGP/PGL automatically reverts to Normal mode when this occurs.

b. A dot row specified in the logo program exceeds the specified vertical

length of the logo. When this occurs, the buffer is flushed until a line

terminator is found, and then logo construction continues normally.

52

LOGO hyphen syntax error in input parameters

The beginning or ending dots are out of order, or a parameter is missing. The

buffer is flushed until a line terminator is found, and then logo construction

continues normally.

53

Insufficient memory to create the LOGO

No more room exists in IGP/PGL memory to construct a logo for the size

specified. When this occurs, the IGP/PGL automatically reverts to Normal

mode. To create space in IGP/PGL memory, delete forms with logo elements

(including the logos) that are no longer required.

54

LOGO format or delimiter error

Some type of format or delimiter error was detected in the Logo command. If

this occurs while specifying the size and name of the logo, the IGP/PGL

automatically reverts to the Normal mode. If this occurs during the actual

construction of the logo, the buffer is flushed until a line terminator is found,

and then logo construction continues normally.

55

LOGO call not previously defined

An attempt was made in the Create Form mode to incorporate an undefined

logo into a form. This error is not generated during the Logo Form mode.

When this error occurs, the buffer is flushed until a line terminator is found,

and then forms creation continues normally.