beautypg.com

Alpha errors – Printronix ThermaLine Series User Manual

Page 340

background image

Error Codes

8–8

Alpha Errors

40

ALPHA leading and trailing delimiters mismatched

The leading delimiter (printable character) of the actual text string was not

matched with an ending delimiter before the line terminator was found.

41

ALPHA starting row SR out of bounds

The starting row parameter in the Alpha command will cause the text string

to print either above or below the limits of the form.

NOTE: Expanded print text strings expand up from the specified row. This

could cause an attempt to print the text string above the top of the

form and generate the error message.

42

ALPHA starting column SC out of bounds

The starting column parameter in the Alpha command is either extending the

alpha string beyond the left margin of the form or the starting column

parameter, plus the actual length of the text is extending the string beyond

the right margin of the page.

43

ALPHA string length > 255 characters

The string contains more than 255 characters.

44

ALPHA format or delimiter error in input parameters

Some type of format or delimiter error was detected in the parameters of the

alpha command. This error is usually caused by one or more of the

following:

a. A missing semicolon;

b. A colon in place of a semicolon;

c. Too many or too few parameters in the command string;

d. Alpha characters instead of numeric characters in the parameters.

45

Insufficient memory to store the ALPHA string

No more room in the IGP/PGL memory exists for another alpha string. The

rest of the Alpha commands are flushed until the Stop command is found.

Processing of the form will then continue normally. To create space in the

IGP/PGL memory, delete forms with alpha string elements that are no longer

required.