Creating standard access rules, Creating standard access rules -9 – Lucent Technologies P550 User Manual
Page 135
![background image](/manuals/163900/135/background.png)
Configuring IP Routing (Layer 3)
Cajun P550/P220 Switch Operation Guide
7-9
There is an implied implicit permit all at the end of the list. Also, you can only have
one list active at a time.
Creating Standard Access Rules
To create standard access rules:
1. In the IP Configuration section of the Web Agent window, click Access Lists.
The IP Access List dialog box opens.
Note: The IP Access List dialog box displays all standard and extended access rules
that have been created. If no rules have been created, the following
statement displays:
No IP Access Rules are currently
configured
.
2. Click Create Standard. Valid numeric values are 1-99.
3. Use Table 7-4 to configure your IP access rules to either filter or prioritize traffic:
4. Click CREATE to save your changes, or CANCEL to restore previous settings.
Table 7-4. IP Access List Setup Parameters
Parameter
Allows you to specify...
Access List Name
The alphanumeric name assigned to the newly-created access
list.
Access Rule Index
The sequence number for each new rule you create. Note that
rules may override each other, so review your current
configuration prior to creating new rules for an access list.
Access Type
The method of handling incoming datagrams based on the IP
access type. Priority levels include:
• Deny/Filter - Allows you to filter out traffic based on the
specified configuration.
• Permit/Fwd pri8 (high) to pri1 (low) - Allows you to
prioritize traffic based on the specified configuration.
• Permit/Fwd with no change in priority - Allows you to
forward traffic with no change in priority.
Source Subnet
• Source Address - The IP address of a subnet that is denied
or granted access to the switch.
• Source Address Wildcard - A range of IP addresses that
are denied or granted access to the switch. Place the
number one (1) in the bit positions you want to ignore.