Siemens Commissioning PC Stations C79000-G8976-C156-07 User Manual
Page 281
A
Notes for Users of Older Versions
281
Commissioning PC Stations - Manual and Quick Start
Release 5/2005
C79000-G8976-C156-07
A.4
Industrial Ethernet - Effects on Older Product Versions
(SIMATIC NET CD 05/2000 and earlier)
Introduction
This section describes what changes are necessary in Industrial Ethernet systems
if you are already using a SIMATIC NET CD 05/2000 product or a previous
version.
PG-1413, S7-1413, TF-1413 up to version 5.2 with Service Pack 2 for
Windows NT 4.0 or Windows 98
Situation:
These products are not supported by the SIMATIC NET CD 07/2001.
Simultaneous installation of these products with products of the new CD 07/2001 is
not permitted and is prevented.
What to do:
Keep using the products of the SIMATIC NET 5/2000 CD if you want to use a CP
1413 in your computer or replace it with a CP 1613.
PG-1613 up to version 2.1 for Windows 2000 Pro or Windows NT 4.0
Situation:
PG operation possible as before.
What to do:
No action necessary
S7-1613 up to version 2.1 for Windows 2000 Pro or Windows NT 4.0
Situation:
S7 project engineering created with the COML S7 program cannot be used.
What to do:
A project engineering configuration created with the COML S7 program must be
recreated with SIMATIC NCM PC V5.1 Service Pack 2 or higher or STEP 7
Version 5.1 Service Pack 2 or higher.
If the project engineering configuration was already created with STEP 7 (XDB),
this STEP 7 project can continue to be used. You only need to download the
project engineering data to the CP/PC station from STEP 7 Version 5.1 Service
Pack 2 or higher.