DCOM Settings with the dcomcnfg System Program

276

Commissioning PC Stations - Manual and Quick Start

Release 5/2005

C79000-G8976-C156-07

It is advisable to register other OPC clients as DCOM objects. The advantage of
this is that you can configure the security settings as described here with
DCOMCNFG without needing to modify system - wide settings.

Security Settings per User Program

You can also make the settings described in the earlier sections using the user
program. To do this, you use the“CoIntializeSecurity ( )” call from the Windows
programming interface with which you can specify the DCOM security.

Notice

Remember that the security settings made in the user program have priority over
the settings made in the DCOM dialog!