beautypg.com

10 adapting mismatched configurations – Siemens Commissioning PC Stations C79000-G8976-C156-07 User Manual

Page 189

background image

13

SIMATIC NCM PC Project Engineering Tool

189

Commissioning PC Stations - Manual and Quick Start
Release 5/2005

C79000-G8976-C156-07

13.10

Adapting Mismatched Configurations

The Station Configuration Editor displays assigned indexes

If you cannot download configuration information to the PC station, this may be
due to a mismatched configuration. The Station Configuration Editor will provide
you with an overview of the indexes allocated to the PC station. This is the tool for
setting up the components installed in the PC station.

Adapting the Configuration

There are two ways of matching up the actual local configuration of the PC station
and the defined configuration as in your project.

S

Adapting the assignment in the defined configuration

Change the assignment of the modules configured on the PC in the defined
project configuration using NCM PC / PC Config so that it matches the
configuration recognized by the Station Configuration Editor.

S

Changing the configuration on the PC station

Using the “Station Configuration Editor” program, you can assign a new index to
a component and add components that are not set for operation as defined in
the project to the defined operating configuration.

You should also read the description of the “Station Configuration Editor” tool in
Chapter 12.