SIMATIC NCM PC Project Engineering Tool

177

Commissioning PC Stations - Manual and Quick Start
Release 5/2005

C79000-G8976-C156-07

13.8

Project Engineering for a PC Station as DP Slave

This section explains how to create the project engineering for a PC station with
the CP 5611 as DP slave.

Two situations can be distinguished:

S

The DP master engineering data was created in NCM/STEP 7 (in the example
as other PC station)

S

The engineering data for the DP master cannot be created in NCM / STEP 7

In both cases, a CP 5611 is used as the DP slave. We assume a project in which a
DP master system has been created (for a description of creating the system, refer
to Section 13.5).

13.8.1

DP Master is Known in NCM / STEP 7

As an example, we first create a PC station that can take on the role of a DP slave.

Follow the steps below:

Follow the steps outlined below:

1.

Open the project with the DP master system.

2.

Insert a PC station from the catalog.

The PC station adopts the role of the DP slave.

3.

Open the PC station in HW Config.

4.

Add a user application of the type OPC server or application in the PC station.

5.

Insert a module of the type CP 5611.