display on two places.
Allow all Windows User Accounts to use this application All users with different Windows
accounts can be allowed to run Witness Pro program.
Upon system failure Select PC’s reaction “Restart program” and “Reboot system” from the
drop-down menu when NVR system is abnormal. For example: Select “Restart program”, the
system will automatically restart Witness Pro program when NVR system is abnormal.
Log out when no user interaction is involved for Logout the Witness Pro program when the user
is inactive NVR over the setting duration.
Exit option Select PC status “Exit program”, “Turn off”, “Log off” or “Restart” from the
drop-down menu after exiting Witness Pro program. For example: Select “Turn off”, the system
will automatically shut down after exiting Witness Pro program.
Auto login The NVR will automatically login by saved username and password in Witness Pro
after reboot.
NetCom Module:
Model: Select the type of control board for the PTZ camera, D/I and D/O devices based on the
installed models.
Checksum: It depends on the type of Speed dome camera. Please refer to the manual of Speed
dome camera.
Com Port: You must select “Auto” from the draw menu of “Com Port “icon when you want
to enable the function of Netcom module.
Baud rate: Select a correct Baud rate to control the Speed dome camera or P/T/Z camera from
Witness NVR board (Default setting is 9600 bps).
You must select “9600” baud rate, enable Checksum icon, and select “Pelco P” or “FastCam
V2” or “SDCI-220” when you install I-View’s FastCam III Speed dome camera series.
PAC-080M Amplifier: You need to connect the PAC-080M public address sever with the
NVR/NVR before enable this function. Select the “Auto” from the drop-down menu of “ Com