CrossPoint / MAV Matrix Switchers • Installation

Sync termination switches (CrossPoint)

c

Sync termination switches — The RGB (CrossPoint) matrix switchers have

input Sync termination switches on the rear panel (figure 2-16) that provide a

way to condition non-TTL sync levels greater than 5 Vp-p. Sync termination

enables the sync to be properly passed from input to selected output(s).

The matrix switchers have two sets of sync termination switches; one for

horizontal or combined sync and a second set for vertical sync.

The CrossPoint 450 Plus matrix switchers have Sync termination switches for

inputs 1 through 8.

The CrossPoint Ultra matrix switchers have Sync termination switches for

inputs 1 through 4.

CrossPoint Ultra

816, 168, 1212, and 1616

CrossPoint Ultra

84, 88, 124, and 128

H SYNC V SYNC

V

V

15

16

15

16

1

4

2

3

1

4

2

3

O U T P U T S

O U T P U T S

I N P U T S

I N P U T S

SYNC

V SYNC

H

HV

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

CrossPoint 450 Plus

2412, 2424, 3216, and 3232

Figure 2-16 — Sync termination switches

Each switch provides the option of selecting either 510 ohms or 75 ohms.

The 75 ohms position is required only for an input with non-TTL sync, greater

than 5 V p-p. The normal position is 510 ohms.

N

An input that produces an out of sync display, a display that is rolling vertically

and/or tearing horizontally, could indicate a non-TTL sync input.
A device that is known to output non-TTL sync levels (greater than 5V p-p)
should be connected to one of the inputs with sync termination switches, and the
switches for that input should be set to the 75 ohm position. If you are not sure,
check the specifications in the user’s manual for the input device.