Programmer’s Guide, cont’d

CrossPoint / MAV Matrix Switchers • Programmer’s Guide

4-18

Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional

description

I/O Grouping (continued)

N

X1^

= Group # (for I/O grouping)

1 through 4 groups (0 = no group)

Read input grouping

E

I

}

X1^

1

X1^

2

X1^

3

...

X1^

n

]

Each

X1^

entry is the group

number assigned to an input
position, starting from input 1.
n

= the maximum number of

inputs for this model.

Example: MAV Plus 2424

E

I

}

See below.

01

Input:

Response = group:

Input 1 in group 1

02 03 04 05 06 07 08 09 10 11 12

1 1 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3

13 14 15 16 17 18 19 20 21 22 23 24

Input 9 not grouped

Input 24 in group 3

Read output grouping

E

O

}

X1^

1

X1^

2

X1^

3

...

X1^

n

]

Each

X1^

entry is the group

number assigned to an output
position, starting from output
1. n = the maximum number
of outputs for this model.

Names

N

X(

= Global or room preset #

00 - 32, 10 maximum for a room preset (00 = current configuration)

X1!

= Name

11 (rooms) or 12 characters (inputs, outputs, and global presets)

11 characters maximum for room names

X1)

= Room # (for room presets)

10 maximum

X!

= Input number

01 – (maximum number of inputs for your model)

Write global preset name

EX(,X1!

NG

}

Nmg

X(,X1!]

Example:

E

1,Security 1NG

}

Nmg01

,

Security 1

]

Name global preset 1
“Security 1”.

Read global preset name

EX(

NG

}

X1!]

Example:

E

2NG

}

Security 2

]

Write room name

EX1),X1!

NR

}

Nmr

X1),X1!]

Example:

E

1

,

Classrm 1NR

}

Nmr01

,

Classrm 1

]

Name room 1 “Classrm 1”.

Read room name

EX1)

NR

}

X1!]

Write room preset name

EX1)

*

X(,X1!

NP

}

Nmp

X1)

*

X(,X1!]

Example:

E

1*3

,

Podium_DVDNP

}

Nmp01*3

,

Podium_DVD

]

Name room 1, preset 3
“Podium_DVD”.

Read room preset name

EX1),X(

NP

}

X1!]

N

• Do not use leading spaces in preset names.

If a preset is unassigned, the

X1!

displays

[unassigned].

If a global preset is saved, but not yet named, the default name is Preset

X(

.

If a room preset is saved, but not yet named, the default name is Rm

X1)

Prst

X(

.

Write input name

EX!,X1!

NI

}

Nmi

X!,X1!]

Example:

E

1

,

Podium camNI

}

Nmi01

,

Podium cam

]

Name input 1 “Podium cam”.

Read input name

EX!

NI

}

X1!]

Write output name

EX!,X1!

NO

}

Nmo

X!,X1!]

Example:

E

1,Main PJ1NO

}

Nmo01,Main PJ1

]

Name output 1 “Main PJ1”.

Read output name

EX!

NO

}

X1!]