Status tab, Updating firmware -13, Ethernet-connected firmware upload -15 – Extron electronic Ultra Series User Manual
Page 165
6-3
CrossPoint / MAV Matrix Switchers • HTML Operation
a
. Does the address include a specific file name, such as
10.13.156.10/file_name.html? If so, the switcher downloads that HTML
page.
b
. Is there a file in the switcher’s memory that is named “index.html”?
If so
, the switcher downloads “index.html” as the default startup page.
c
. If neither of the above conditions is true, the switcher downloads the
factory-installed default startup page, “nortxe_index.html” (figure 6-2),
also known as the System Status page.
Status Tab
System Status page
The System Status page (figure 6-2) provides an overall view of the status of the
matrix switcher, including the primary and secondary power supply status, the
individual voltages, and the fan status (if applicable). The System Status page is
the default page that the switcher downloads when you connect to the switcher.
Access the System Status page from other pages by clicking the Status tab.
DSVP
Refresh
Figure 6-2 — System Status page
Components that are operating properly are indicated in green.
Failures are indicated in red.
Not displayed for the CrossPoint or MAV
N
Smaller switchers (16 x 16 matrix sizes and smaller) do not show the power
supply and fan status blocks.
The system status page periodically updates itself to reflect the latest status of the
switcher components.