4-9

CrossPoint / MAV Matrix Switchers • Programmer’s Guide

Command/Response Table for SIS Commands

Symbol definitions

Symbols are used throughout the table to represent variables in the command/

response fields. Command and response examples are shown throughout the table.

N Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit numbers. All input and output numbers are

reported as 2-digit numbers in the response.

]

= CR/LF (carriage return/line feed) (hex 0D 0A)

}

= Carriage return (no line feed, hex 0D))

= Space character

E

= Escape key (hex 1B)

X!

= Input number

01 – (maximum number of inputs for your model)

X@

= Input number (for tie)

00 – (maximum number of inputs for your model) (00 = untied)

X#

= Output number

01 – (maximum number of outputs for your model)

X$

= Mute, Lock mode, power supply

0 = off/mode 0/not OK

1 = on/mode 1/OK

2 = mode 2

X%

= Audio gain

0 – 24 (1 dB/step)

X^

= Numeric dB value

–18 to +24 (45 steps of gain or attenuation) (Default = 0 dB)

X&

= Audio attenuation

1 – 18 (1 dB/step)

X*

= Volume adjustment range

0 – 64 (1 dB/step except for 0-to-1, which is 22 dB)

(default = 64 [0 dB])

(See the table on page 4-12.)

X(

= Global or room preset #

00 - 32, 10 maximum for a room preset (00 = current configuration)

N

A Room preset is a stored configuration with all of the outputs assigned to a single room. When a room preset is retrieved from

memory, it becomes the current configuration.

X1)

= Room # (for room presets)

10 max. (Each can have up to 10 presets (

X(

s) assigned.)

N A Room is a subset of operator-selected outputs that relate to each other. The CrossPoint or MAV Plus switchers support up to 10

rooms, each of which can consist of from 1 to 16 outputs.

X1!

= Name

12 characters maximum for input, output, and global preset names

11 characters maximum for room names

Upper- and lower-case alphanumeric characters and

_ / and spaces are valid.

N

The following characters are invalid in the name: {space} ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.

X1@

= Video/audio mute:

0 = no mutes

1 = video mute

2 = audio mute

3 = video and audio mute

X1#

= Sync frequency

xxx

.xx (frequency in hZ [V] or kHz [H])

X1$

= Connection status

0 = no input connected

1 = input connected

X1%

= RGB delay interval

Delay in 1/2 second increments (10 maximum)

X1^

= Group # (for I/O grouping)

1 through 4 groups (0 = no group)

X1&

= Inputs

Total number of inputs for this switcher

X1*

= Outputs

Total number of outputs for this switcher

X1(

= Part number

60-nnn-nn (See appendix B, “Reference Information”.)

X2)

= Firmware version number to second decimal place (x.xx)

X2!

= Verbose firmware version-description-upload date/time.

See the

Query controller firmware version (verbose) command on page 4-20.

X2@

= Voltage

Positive or negative voltage and magnitude

X2#

= Temperature

Degrees Fahrenheit

X2$

= Fan speed

RPM