beautypg.com

Switcher error responses – Extron electronic Ultra Series User Manual

Page 117

background image

4-7

CrossPoint / MAV Matrix Switchers • Programmer’s Guide

Sprnn

]

The switcher initiates the Spr message when a preset has been saved from the front

panel. nn is the preset number.
Rprnn

]

The switcher initiates the Rpr message when a preset has been recalled from the

front panel. nn is the preset number.
Innn•Audxx

]

The switcher initiates the Aud message when a front panel input audio level change

has occurred. nn is the input number and xx is the dB level.
Outnn•Volxx

]

The switcher initiates the Vol message when a front panel output audio volume

change has occurred. nn is the output number and xx is the volume level.
Vmtnnx

]

The switcher initiates the Vmt message when a video output mute is toggled on

or off from the front panel. “nn” is the output number, • is a space, and “x” is the

mute status: 1 = on, 0 = off.
Amtnnx

]

The switcher initiates the Amt message when an audio or RS-232 output mute is

toggled on or off from the front panel. nn is the output number, • is a space, and x

is the mute status: 1 = on, 0 = off.
Exen

]

The switcher initiates the Exe message when executive mode is toggled on or off

from the front panel. n is the executive mode: 0, 1, or 2.

Switcher Error Responses

When the switcher receives an SIS command and determines that it is valid, it

performs the command and sends a response to the host device. If the switcher

is unable to perform the command because the command is invalid or contains

invalid parameters, the switcher returns an error response to the host. The error

response codes are:

E01 — Invalid input channel number (too large)

E10 — Invalid command

E11 — Invalid preset number

E12 — Invalid output number (too large)

E13 — Invalid value (out of range)

E14 — Illegal command for this configuration

E17 — Timeout (caused only by direct write of global presets)

E21 — Invalid room number

E22 — Busy

E24 — Priviledge violation (Users have access to all view and read

commands (other than the Adminstrator password), and can

create ties, presets, and video and audio mutes

E25 — Device not present

E26 — Maximum number of connections exceeded

E27 — Invalid event number

E28 — Bad filename / file not found