CrossPoint / MAV Matrix Switchers • Programmer’s Guide

Default IP addresses

To access the CrossPoint or MAV Plus switcher via the LAN port, you need the

Extron IP address, and may need the subnet mask and the gateway address. If the

IP address has been changed to an address comprised of words and characters,

you can determine the actual numeric IP address using the ping (ICMP) utility (see

appendix A, “Ethernet Connection”, for more details). If the addresses have not

been changed, the factory-specified defaults are:

• IP address

192.168.254.254

• Gateway address 0.0.0.0

• Subnet mask

255.255.0.0

Establishing a connection

Establish a network connection to a CrossPoint or MAV Plus switcher as follows:

1

.

Open a TCP socket to port 23 using the switcher’s IP address.

N

If the local system administrators have not changed the value, the factory-

specified default, 192.168.254.254, is the correct value for this field.

The switcher responds with a copyright message including the date, the name

of the product, firmware version, part number, and the current date/time.

N

If the switcher is not password-protected, the device is ready to accept SIS

commands immediately after it sends the copyright message.

N

If the switcher is password-protected, a

password prompt appears below the

copyright message.

2

.

If the switcher is password protected, enter the appropriate administrator or

user password.

If the password is accepted, the switcher responds with

Login User or

Login Administrator.

If the password is not accepted, the

Password prompt reappears.

Connection Timeouts

The Ethernet link times out after a designated period of time of no communications.

By default, this timeout value is set to 5 minutes but the value can be changed. See

the Configure port timeout commands on page 4-25.

N

Extron recommends leaving the default timeout at 5 minutes and periodically

issuing the Query (Q) command to keep the connection active. If there are long
idle periods, Extron recommends disconnecting the socket and reopening the
connection when another command must be sent.

Number of connections

A CrossPoint or MAV Plus switcher can have up to 200 simultaneous TCP

connections, including all http sockets and Telnet connections. When the

connection limit is reached, the switcher accepts no new connections until some

have been closed. No error message or indication is given that the connection limit

has been reached. To maximize performance of an IP Link device, the number of

connections should stay low and unnecessary open sockets should be closed.