CrossPoint / MAV Matrix Switchers • Programmer’s Guide

Command/response table for SIS commands (continued)

Command

ASCII command

(host to switcher)

Response

(switcher to host)

Additional

description

Digital Sync Validation Processing (DSVP) (CrossPoint)

N

X!

= Global or room preset #

00 - 32, 10 maximum for a room preset (00 = current configuration)

X1#

= Sync frequency

xxx.xx (frequency in hZ [V] or kHz [H]))

X1$

= Connection status

0 = no input connected

1 = input connected

List individual sync
frequency

X!

LS

X1#,X1#]

Listed as horizontal frequency,
vertical frequency.

Example:

2LS

031.50

,

060.00

]

Input 2 horizontal frequency
is 31.5 khZ and its vertical
frequency is 60 Hz.

N

The matrix switcher returns 000.00,000.00 if there is no connection or sync frequencies are not applicable.

View connections

0LS

X1$

1

X1$

2

X1$

3

...

X1$

n

]

Each

X1$

response is

the connection status
(0 = no input detected,
1 = input detected) of
an input, starting from input 1.
n

is the maximum number of

inputs for this model.

RGB delay (CrossPoint)

N

X#

= Output number

01 – (maximum number of outputs for your model)

X1%

= RGB delay interval

Delay in 1/2 second increments (10 maximum)

Set RGB delay

EX#

*

X1%

D

}

Out

X#

•Dly

X1%

*1

]

Example:

E

13*7D

}

Out13•Dly07

]

Set the RGB interval for ties
to output 13 to 3.5 seconds
(7 x 0.5 sec.).

View RGB delay

EX#

D

}

X1%]

Example:

E

14D

}

05

]

Output 14 interval is
2.5 seconds (5 x 0.5 sec.).

I/O Grouping

N

X1^

= Group # (for I/O grouping)

1 through 4 groups (0 = no group)

N

The group that is assigned in each of the following I/O grouping commands (

X1^

) must be 1, 2, 3, 4, or 0 (not grouped).

Write input grouping

EX1^

1

X1^

2

...

X1^

n

I

}

Gri

X1^

1

X1^

2

X1^

3

...

X1^

n

]

Each

X1^

entry is the group

number assigned to an input
position, starting from input 1.
n

= the maximum number of

inputs for this model.

Example:
CrossPoint 450 Plus 3232

E

40...33I

}

See below.

01

Input:

Gri

Response #s = group:

Input 1 in group 4

02 03 04 05 06 07 08 09 10 11 12

4 0 1 3 3 0 0 0 0 4 4 4 4 1 1 2 2 1 2 2 3 3 3 3

13 14 15 16 17 18 19 20 21 22 23 24

Input 2 not grouped

2 1 2 2 3 3 3 3

25 26 27 28 29 30 31 32

Input 32 in group 3

Input 1 - group 4,
input 2 - group 0 (ungrouped),
... input 31 - group 3,
input 32 - group 3.

Write output grouping

EX1^

1

X1^

2

...

X1^

n

O

}

Gro

X1^

1

X1^

2

X1^

3

...

X1^

n

]

Each

X1^

entry is the group

number assigned to an output
position, starting from output
1. n = the maximum number