Reset Mode Comparison/Summary

Mode

Activation

Result

Purpose/Notes

1

Hold down the recessed Reset button

while applying power to the switcher.

N

After a mode 1 reset is

performed, update the
switcher’s firmware to the
latest version. Do not operate
the switcher firmware version
that results from the mode
1 reset. If you want to use
the factory default firmware,
you must upload that version
again. See chapter 5, “Matrix
Software”, for details on
uploading firmware.

The switcher reverts to the factory default
firmware.

Event scripting will not start if the

switcher is powered on in this mode. All user files

and settings (drivers, adjustments, IP settings, etc)

are maintained.

N

If you do not want to update firmware, or

you performed a mode 1 reset by mistake,
cycle power to the switcher to return to the
firmware version that was running before
the mode 1 reset. Use the 0Q SIS command
to confirm that the factory default firmware
is no longer running (look for the asterisk
[*] following the version number.

Use mode 1 to revert

to the factory default

firmware version if

incompatibility issues

arise with user-loaded

firmware.

3

Hold down the Reset button for about

3 seconds, until the Reset LED blinks

once, then press Reset momentarily

(<1 second) within 1 second.

Mode 3 turns events on or off.

During resetting,

the Reset LED flashes 2 times if events are starting,

3 times if events are stopping.

Mode 3 is useful for

troubleshooting.

4

Hold down the Reset button for

about 6 seconds, until the Reset LED

blinks twice (once at 3 seconds and

again at 6 seconds). Then press Reset

momentarily (<1 second) within 1

second.

Mode 4:
• Enables ARP capability.

• Sets the IP address to the factory default.

• Sets the subnet address to the factory default.

• Sets the gateway address to the factory default.

• Sets port mapping to the factory default.

• Turns DHCP off.

• Turn events off.

The Reset LED flashes four times in quick

succession during the reset.

Mode 4 enables you

to set IP address

information using ARP

and the MAC address.

5

Hold down the Reset button for

about 9 seconds, until the Reset LED

blinks three times (once at 3 seconds,

again at 6 seconds, and then again

at 9 seconds). Then press Reset

momentarily (<1 second) within 1

second.

N

Mode 5 reset clears most

adjustments. To save these
settings, use the Windows-
based Matrix Switchers
Control Program and the
File

> Save MATRIX

settings as...

selection before

you perform this reset (See
chapter 5, “Matrix Software”).

Mode 5 performs a complete reset to factory
defaults (with the exception of the firmware):
• Does everything mode 4 does.

• Resets almost all real time adjustments:

clears all ties and presets, clears all audio or

RS-232 mutes, clears all I/O grouping, clears

all RGB delay settings to zero, and clears all

input and output audio settings.

• Resets all IP options.

• Removes/clears all files for the switcher.

The reset LED flashes four times in quick

succession during the reset.

Mode 5 is useful if

you want to start over

with configuration and

uploading and also to

replace events.

For different reset levels, press and hold the button while the switcher is running or