beautypg.com

Print head cleaning method, Types of cleaning and order of implementation, Diagnostic cleaning – Epson SureLab D1070 Professional Minilab Printer User Manual

Page 91

background image

SL-D1000 Series User's Guide

Using the Maintenance Tool (Windows)

91

If none of the check pattern is missing, then the
print head nozzles are not clogged.

Example of clogged nozzles

If part of the pattern is missing, then the print
head nozzles are clogged. The print head needs
to be cleaned.

U

“Print Head Cleaning Method” on page 91

Print Head Cleaning Method

Types of Cleaning and Order of
Implementation

There are two types of cleaning,

Forced Cleaning

,

which is cleaning the print head manually, and

Diagnostic Cleaning

, which detects clogged nozzles

and cleans the print head automatically.

First, implement

Diagnostic Cleaning

.

After doing that, when "Clogged nozzles detected.
Perform [Forced Cleaning].” is displayed in

Printer

history

on the main screen, implement

Diagnostic

Cleaning

.

If the clogged nozzles are not cleared after repeating

Diagnostic Cleaning

three times, then do

Forced

Cleaning

set to

Power

.

Diagnostic Cleaning

1

Select a printer, in the printer list area on the
main screen, on which to execute cleaning.

When you select multiple printers, press and
hold

Ctrl

as you select the targeted printers.

See the following for more details on the main
screen.

U

“Explanation of the Main Screen” on page

81

If an error is displayed for the printer you want
to select, clear the error before selecting it.

2

In

Printer maintenance

-

Diagnostic Cleaning

,

select

Normal

or

Saving Ink

, and then click

Execute

.

Normal

prints a check pattern on roll paper and

automatically checks the status of the nozzles.
Roll paper must be loaded on the printer.

Saving Ink

does not print a check pattern and

automatically checks the state of the nozzles,
whether roll paper or cut sheets are loaded on
the printer.

The nozzle check starts and cleaning is executed
if necessary.

The time needed for cleaning varies according
to the status of the nozzles.

3

Check the results of Diagnostic Cleaning in the
message displayed in

Printer history

.

When "Clogged nozzles detected. Perform
[Forced Cleaning].” is displayed, execute

Diagnostic Cleaning

again.

If "Auto Nozzle Check has failed." is displayed,
contact service support.