Auto Nozzle Check Settings tab
In this section you can do advanced settings for auto nozzle check to confirm the state of the nozzles when the
printer is turned on and at specified times so that the nozzles are automatically cleaned if they clog.
The configuration and functions of the
Auto Nozzle Check Settings
tab in the Printer settings screen are shown
below.
After changing the settings in items
B
to
G
, the changes are applied by clicking
Set
.
Item
Functions
A
Apply to all printers
By selecting this, the results of settings changed in
B
to
G
are batch applied to all
printers displayed in the printer list area at the top of the screen.
Select this and then change the settings in
B
to
G
, and then click
Set
.
B
Auto Nozzle Check Settings
Set the conditions in which an automatic nozzle check is done. Select one of the
following.
O
High quality
Prints a check pattern on roll paper and automatically checks the state of the
nozzles. Nozzles are checked in the same way as when the printer is turned on
too.
Roll paper must always be loaded on the printer.
O
Normal
When printing on roll paper, prints a check pattern on roll paper and
automatically checks the state of the nozzles. When printing on cut sheets,
does not print a check pattern and automatically checks the state of the
nozzles.
When roll paper is loaded, nozzles are checked in the same way as when the
printer is turned on too.
O
Saving Ink
Does not print a check pattern and automatically checks the state of the
nozzles, whether roll paper or cut sheets are loaded on the printer. Nozzles are
checked in the same way as when the printer is turned on too.
O
Off
Nozzles are not checked automatically. Select his when you want to visually
confirm the printed check pattern to confirm the state of the nozzles.
O
Default
Returns all the settings (
B
to
G
) in the
Auto Nozzle Check Settings
tab to
the manufacturer’s settings.