Auto Nozzle Check Settings tab

In this section you can do advanced settings for auto nozzle check to confirm the state of the nozzles when the
printer is turned on and at specified times so that the nozzles are automatically cleaned if they clog.

The configuration and functions of the

Auto Nozzle Check Settings

tab in the Printer settings screen are shown

below.

After changing the settings in items

B

to

G

, the changes are applied by clicking

Set

.

Item

Functions

A

Apply to all printers

By selecting this, the results of settings changed in

B

to

G

are batch applied to all

printers displayed in the printer list area at the top of the screen.

Select this and then change the settings in

B

to

G

, and then click

Set

.

B

Auto Nozzle Check Settings

Set the conditions in which an automatic nozzle check is done. Select one of the
following.

O

High quality

Prints a check pattern on roll paper and automatically checks the state of the
nozzles. Nozzles are checked in the same way as when the printer is turned on
too.

Roll paper must always be loaded on the printer.

O

Normal

When printing on roll paper, prints a check pattern on roll paper and
automatically checks the state of the nozzles. When printing on cut sheets,
does not print a check pattern and automatically checks the state of the
nozzles.

When roll paper is loaded, nozzles are checked in the same way as when the
printer is turned on too.

O

Saving Ink

Does not print a check pattern and automatically checks the state of the
nozzles, whether roll paper or cut sheets are loaded on the printer. Nozzles are
checked in the same way as when the printer is turned on too.

O

Off

Nozzles are not checked automatically. Select his when you want to visually
confirm the printed check pattern to confirm the state of the nozzles.

O

Default

Returns all the settings (

B

to

G

) in the

Auto Nozzle Check Settings

tab to

the manufacturer’s settings.