143

X.25 Line Subscription Worksheet

The following settings are available when configuring X.25.

Parameter

Options/Range

Default

Value

Node Type

DTE or DCE

DTE

Local DTE address

1-15

Default window size

1-7

2

Maximum window size

1-7

7

Packet format

Basic or extended

extended

Default packet size

64-1024

128

Maximum packet size

Default packet
size to 1024

256

X.25 version

1984 or 1988

1984

Maximum retry count

0-99

3

Permanent Virtual Circuits (PVCs)

Start, number

1,0

Incoming Virtual circuits (IVCs)

2,0

Two-Way Virtual Circuits (TVCs)

1,1

Outgoing Virtual Circuits (OVCs)

1,0

T20:

0-999

60

T21:

0-999

60

T22:

0-999

60

T23

0-999

60

Acknowledge

0-9999

20