background image

Freq Ref 3

Freq Ref 1

Forward/Reverse Run/Stop

Multi-Step Speed 1

Multi-Step Speed 2

Frequency
Reference

Freq Ref 4

Freq Ref 2

ON

ON

ON

OFF

OFF

ON

Figure 4.15 4-Step Speed Time Chart

n

Setting Procedure

Step

Display/Result

1.

Turn on the power to the drive. The initial display appears.

2.

Set the frequencies listed below to the specified parameters:
1. d1-01 = 5 Hz: Step 1

<1>

2. d1-02 = 20 Hz: Step 2

3. d1-03 = 50 Hz: Step 3

4. d1-04 = 60 Hz: Step 4

3.

Press the

key until the initial display appears.

4.

turns on.