beautypg.com

N: advanced performance set-up, O: operator related parameters, B.2 parameter table – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 233

background image

u

n: Advanced Performance Set-Up

The n parameters are used to adjust more advanced performance characteristics.

No.

Name

Description

Range Def. Mode Addr.

Hex

Pg.

n1: Hunting Prevention

Use n1 parameters to configure hunting prevention operation.

n1-02 Hunting

Prevention

Gain Setting

Sets the gain for the Hunting Prevention Function.

If the motor vibrates while lightly loaded, increase the

gain by 0.1 until vibration ceases.

If the motor stalls, decrease the gain by 0.1 until the

stalling ceases.

0.00 to

2.50

1.00

O

581

n3: Overexcitation Braking

Use n3 parameters to configure the overexcitation braking function.

n3-13

Overexcitation
Deceleration
Gain

Applies a gain to the V/f pattern during deceleration

(L3-04 = 4). Returns to normal values after ramp to

stop or at re-acceleration.

To increase the braking power of overexcitation,

increase the gain by 1.25 to 1.30.

1.00 to

1.40

1.10

O

531

u

o: Operator Related Parameters

o parameters are used to set up the LED digital operator displays.

No.

Name

Description

Range Def. Mode Addr.

Hex

Pg.

o1: Display Settings

Use o1 parameters to configure the digital operator display.

o1-02

<1>

User Monitor

Selection

After Power

Up

Selects the information displayed when power is

applied.

1: Frequency Reference (U1-01)

2: Forward/Reverse

3: Output Frequency (U1-02)

4: Output Current (U1-03)

1 to 4

1

O

501

o1-03

Digital

Operator

Display

Selection

Sets the units to display the frequency reference and

output frequency.

0: 0.01 Hz

1: 0.01% (100% = E1-04)

0, 1

0

O

502

o2: Operator Keypad Functions

Use o2 parameters to configure LED digital operator key functions.

o2-02 STOP Key

Function

Selection

Determines if the STOP key on the digital operator

will stop the drive when operating from the external

terminals or via serial communication.

0: Disabled

1: Enabled

0, 1

1

O

506

B.2 Parameter Table

YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide

233

B

Parameter List