B.3 defaults by drive model and duty rating nd/hd, B.3 defaults by drive model and duty, Rating nd/hd – Yaskawa J1000 Compact V/f Control Drive User Manual
Page 238

B.3
Defaults by Drive Model and Duty Rating
ND/HD
Table B.2 Single-Phase, 200 V Class Drives Default Settings by Drive Capacity and ND/HD Settings
No.
Description
Unit
Default Settings
−
Model
−
BA0001
BA0002
BA0003
o2-04
Drive Model Selection
Hex
30
31
32
C6-01
Normal/Heavy Duty
−
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
−
Motor rated power
kW
0.1
0.18
0.25
0.37
0.55
0.75
C6-02
Carrier frequency
−
4
7
4
7
4
7
E2-01
Motor rated current
A
0.60
1.10
1.10
1.90
1.90
3.30
E2-02
Motor rated slip
Hz
2.50
2.60
2.60
2.90
2.90
2.50
E2-03
Motor no-load current
A
0.40
0.80
0.80
1.20
1.20
1.80
E2-05
Motor line-to-line resistance
Ω
35.98
20.56
20.56
9.84
9.842
5.156
−
Momentary power loss ride-
through time
s
0.1
0.1
0.1
0.1
0.1
0.1
−
Mom. power loss Baseblock
time
s
0.2
0.2
0.2
0.2
0.2
0.3
No.
Description
Unit
Default Settings
−
Model
−
BA0006
BA0010
o2-04
Drive Model Selection
Hex
33
34
C6-01
Normal/Heavy Duty
−
HD
ND
HD
ND
0
1
0
1
C6-02
Carrier frequency
−
4
7
3
7
E2-01
Motor rated current
A
3.30
6.20
6.20
8.50
E2-02
Motor rated slip
Hz
2.50
2.60
2.60
2.90
E2-03
Motor no-load current
A
1.80
2.80
2.80
3.00
E2-05
Motor line-to-line resistance
Ω
5.156
1.997
1.997
1.601
−
Momentary power loss ride-through time
s
0.2
0.2
0.3
0.3
−
Momentary power loss Baseblock time
s
0.3
0.4
0.4
0.5
B.3 Defaults by Drive Model and Duty Rating ND/HD
238
YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide