B.2 parameter table – Yaskawa J1000 Compact V/f Control Drive User Manual
Page 225

H1 Multi-Function Digital Input Selections
H1-
Setting
Function
Description
Page
20 to 2F External Fault
20: N.O., Always Detected, Ramp To Stop
21: N.C., Always Detected, Ramp To Stop
22: N.O., During Run, Ramp To Stop
23: N.C., During Run, Ramp To Stop
24: N.O., Always Detected, Coast To Stop
25: N.C., Always Detected, Coast To Stop
26: N.O., During Run, Coast To Stop
27: N.C., During Run, Coast To Stop
28: N.O., Always Detected, Fast-stop
29: N.C., Always Detected, Fast-stop
2A: N.O., During Run, Fast-stop
2B: N.C., During Run, Fast-stop
2C: N.O., Always Detected, Alarm Only (continue running)
2D: N.C., Always Detected, Alarm Only (continue running)
2E: N.O., During Run, Alarm Only (continue running)
2F: N.C., During Run, Alarm Only (continue running)
–
40
Forward Run Command
(2-Wire sequence)
Open: Stop
Closed: Forward run
–
41
Reverse Run Command
(2-Wire sequence)
Open: Stop
Closed: Reverse run
–
61
External Search Command 1
Closed: Activates Current Detection Speed Search from the
max. output frequency (E1-04)
–
62
External Search Command 2
Closed: Activates Current Detection Speed Search from the
frequency reference
–
67
Communications Test Mode
Tests the MEMOBUS/Modbus RS-422/485 interface.
–
No.
Name
Description
Range Def. Mode Addr.
Hex
Pg.
H2: Multi-Function Digital Output MA-MB-MC
Use H2 parameters to assign functions to the multi-function digital output MA-MB-MC.
H2-01
Terminal MA,
MB and MC
Function
Selection
(relay)
Refer to H2 Multi-Function Digital Output Settings
on page
for a description of setting values.
0 to 13D
E
O
40B
H2 Multi-Function Digital Output Settings
H2-01
Setting
Function
Description
Page
0
During Run
Closed: A Run command is active or voltage is output
–
1
Zero Speed
Closed: Output frequency is 0
–
2
Speed Agree 1
Closed: Output frequency equals the speed reference (plus or
minus 2 Hz hysteresis)
–
4
Frequency Detection 1
Closed: Output frequency is less than or equal to the value in
L4-01 with 2 Hz hysteresis
–
B.2 Parameter Table
YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide
225
B
Parameter List