H

X

L

W

Y

LINE

A

PE

LOAD

Figure C.5 EMC Filter Dimensions

n

DC Link Chokes for IEC/EN 61000-3-2 Compliance

Table C.6 DC Link Chokes for Harmonics Reduction

Drive Model

DC Link Choke

Model

Rating

200V Three-Phase Units

2A0004

UZDA-B

5.4 A

8 mH

2A0006

400 V Three-Phase Units

4A0002

UZDA-B

3.2 A

28 mH

4A0004

Note:

Models not listed in the above table do not require a DC link choke for EMC compliance.