Table B.3 Three-Phase, 200 V Class Drives Default Settings by Drive Capacity and ND/HD Setting
No.
Description
Unit
Default Settings
−
Model
−
2A0001
2A0002
2A0004
2A0006
2A0010
o2-04
Drive Model Selection Hex
60
61
62
63
65
C6-01
Normal/Heavy Duty
−
HD
ND
HD
ND
HD
ND
HD
ND
HD
ND
0
1
0
1
0
1
0
1
0
1
−
Motor rated power
kW
0.1
0.18 0.25 0.37 0.55 0.75
1.1
1.1
1.5
2.2
C6-02
Carrier frequency
−
4
7
4
7
4
7
4
7
3
7
E2-01
Motor rated current
A
0.60 1.10 1.10 1.90 1.90 3.30 3.30 4.90 6.20 8.50
E2-02
Motor rated slip
Hz
2.50 2.60 2.60 2.90 2.90 2.50 2.50 2.60 2.60 2.90
E2-03
Motor no-load current
A
0.40 0.80 0.80 1.20 1.20 1.80 1.80 2.30 2.80 3.00
E2-05
Motor line-to-line
resistance
Ω
35.98 20.56 20.56
9.84
9.842 5.156 5.156 3.577 1.997 1.601
−
Momentary power loss
ride-through time
s
0.1
0.1
0.1
0.1
0.1
0.1
0.2
0.2
0.3
0.3
−
Momentary power loss
Baseblock time
s
0.2
0.2
0.2
0.2
0.2
0.3
0.3
0.4
0.4
0.5
No.
Description
Unit
Default Settings
−
Model
−
2A0012
2A0020
o2-04
Drive Model Selection
Hex
66
68
C6-01
Normal/Heavy Duty
−
HD
ND
HD
ND
0
1
0
1
−
Motor rated power
kW
2.2
3.0
4.0
5.5
C6-02
Carrier frequency
−
3
7
3
7
E2-01
Motor rated current
A
8.50
11.40
14.0
19.60
E2-02
Motor rated slip
Hz
2.90
2.70
2.73
1.50
E2-03
Motor no-load current
A
3.00
3.70
4.50
5.10
E2-05
Motor line-to-line resistance
Ω
1.601
1.034
0.771
0.399
−
Momentary power loss ride-
through time
s
0.5
0.5
1
1
−
Momentary power loss Baseblock
time
s
0.5
0.5
0.6
0.7
B.3 Defaults by Drive Model and Duty Rating ND/HD
YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide
239
B