7 diagnosing and resetting faults, Fault occurs simultaneously with power loss, If the drive still has power after a fault occurs – Yaskawa J1000 Compact V/f Control Drive User Manual
Page 149: Viewing fault history data after fault, Diagnosing and resetting faults, Drive

5.7
Diagnosing and Resetting Faults
When a fault occurs and the drive stops, follow the instructions below to remove whatever
conditions triggered the fault, then restart the drive.
u
Fault Occurs Simultaneously with Power Loss
WARNING! Electrical Shock Hazard. Ensure there are no short circuits between the main circuit terminals
(R/L1, S/L2, and T/L3) or between the ground and main circuit terminals before restarting the drive. Failure
to comply may result in serious injury or death and will cause damage to equipment.
1.
Turn on the drive input power.
2.
Remove the cause of the fault and reset.
Note:
1
.
To find out what faults were triggered, Check U2-02 (Fault History) to determine the faults
that have been triggered.
2
.
If the fault continues to be displayed after cycling power, remove the cause of the fault and
reset.
u
If the Drive Still has Power After a Fault Occurs
1.
Look at the LED operator for information on the fault that occurred.
2.
Refer to Fault Displays, Causes, and Possible Solutions on page 130
.
3.
Reset the fault.
Refer to Fault Reset Methods on page 150
.
u
Viewing Fault History Data After Fault
Step
Display/Result
1. Turn on the drive input power. The first screen displays.
STOP
2.
Press
until the monitor screen is displayed.
3.
Press
to display the parameter setting screen.
4.
Press
and > until U2-02 (Fault History) is displayed.
5.
Press
to view previous fault (here, EF3).
5.7 Diagnosing and Resetting Faults
YASKAWA ELECTRIC TOEP C710606 26D YASKAWA AC Drive – J1000 Quick Start Guide
149
5
Troubleshooting