beautypg.com

Changing analog output settings, 5 basic operation – Yaskawa J1000 Compact V/f Control Drive User Manual

Page 106

background image

No.

Parameter Name

Description

H4-01

Terminal AM Monitor

Selection

Select the data to output through multi-function analog output terminal AM.

Set the desired monitor parameter to the digits available in U-. For

example, enter “103” for U1-03.

When using this terminal as a through terminal or when not using it at all, set

“000” or “031”.

H4-02

<1>

Terminal AM Output Gain

Sets the voltage level gain of terminal AM. The bias to be added ranges from

0 to +/- 10% when 10 V is assumed to be 100%.

H4-03

<1>

Terminal AM Bias Setting

Sets the voltage level bias for terminal AM.

The bias added is 0 to ±10% with a maximum voltage output of 10 V as 100%.

<1>

The parameter can be changed during run.

n

Changing Analog Output Settings

The following example illustrates how to program analog output terminal AM to generate a

signal proportional to drive output current (monitor U1-03).

Using H4-01 to Display Monitor Contents

Step

Display/Result

1.

Turn on the power to the drive. The initial display appears.

2.

Press

until the Parameter setting menu is displayed.

3.

Press

to enter the Parameter setting menu.

4.

Press

and

to select H4-01.

5.

Press

to display the value currently set to H4-01.

6.

Press

and

to set the output current (103).

7.

Save the setting by pressing

.

8.

The display automatically returns to the parameter setting menu.

9.

Press the

key until back at the Top Screen.

Adjusting the Analog Output Terminal Voltage with H4-02 and H4-03

Note:

This example continues from Step 3 in the previous example.

4.5 Basic Operation

106