(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 8 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
Main Circuit Terminal
F7
L1000A
Comments
/
2
―
200/
2
200
―
400/
2
400
―
Grounding: 200 V class: Ground to 100
Ω or less
400 V class: Ground to 10
Ω or less
Control Terminals and Signal Levels
•
Terminal function differences between F7 and L1000A are listed in the table below.
•
The table indicates terminals in F7 that do not exist in L1000A.
•
Terminals H1 and H2 in the L1000A are for the Safe Disable feature.
Do not remove the jumper between H1-HC and H2-HC.
Control Circuit
Terminal
Signal Level
F7
L1000A
Name
F7
L1000A
S1
F7 (Closed: Forward Run, Open: Stop)
L1000A (Closed: Up, Open: Stop)
S2
F7 (Closed: Reverse Rrun, Open: Stop)
L1000A (Closed: Down, Open: Stop)
S3
Multi-Function Input Selection 1
F7 (External fault, N.O.)
L1000A (Nominal Speed)
S4
Multi-Function Input Selection 2
F7 (Fault reset)
L1000A (Inspection Operation)
S5
Multi-Function Input Selection 3
F7 (Multi-Step Speed Reference 1)
L1000A (Intermediate Speed 1)
S6
Multi-Function Input Selection 4
F7 (Multi-Step Speed Reference 2)
L1000A (Leveling Speed)
S7
Multi-Function Input Selection 5
F7 (Jog)
L1000A (Not Used)
S8
Multi-Function Input Selection 6
F7 (External baseblock command)
L1000A (Not Used)
Photocoupler insulation
24 Vdc, 8 mA
Use the wire jumper between SC and SN or between SC
and SP to select sinking or sourcing, and to select the
power supply.
SC
Sequence Control Input Common
Common Control Signal
(2 terminals)
(2 terminals)