beautypg.com

Terminal connections – Yaskawa F7 to L1000A User Manual

Page 7

background image

(Header Title) Application Note




Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.

©2010 www.yaskawa.com September 9, 2010 7 of 57

Subject: Transition Guide

Product: L1000A

Document: PL.L1000A.01

Title: Product Transition Guide – F7 to L1000A

Product Transition Guide – F7 to L1000A

F7

L1000A

Power
Supply

Model
CIMR-F7U

Rated
Output
Capacity
(HP)

Rated
Output
Current
(A)

Carrier
Frequency
(kHz)

Model
CIMR-LU

Rated
Output
Capacity
(HP)

Rated
Output
Current
(A)

Carrier
Frequency
(kHz)

43P7 5 6.9

4A0009

5 9.2

45P5 7.5 11.4

4A0015 7.5 14.8

47P5 10 15.5

4A0018 10 18

4011 15 21.9

4A0024

15 24

4015 20 28.3

4A0031

20 31

4018 25 35.6

4A0039

25 39

4022

30 41

4A0045

30 45

4030 40 50.5

4A0060

40 60

4037 50 63.2

4A0075

50 75

4045 60 76.6

4A0091

60 91

4055 75 94.3

4A0112

75 92

4075 100 110.4

4A0150

100 123

4090 125 132.5

4A0180

125 148

4110 150 159

4A0216

150 177

400 V

3-Phase

4132 200 194.4

8

4A0260 200 213

8

Terminal Connections

Main Circuit Terminals

Note:

The F7 and L1000A drives may have different terminal sizes (depending on capacity). The terminals must be carefully

checked before replacement.

Main Circuit Terminal

F7

L1000A

Comments

R/L1 R/L1

S/L2 S/L2

T/L3 T/L3

Main circuit power supply input

R1/L11

S1/L21

T1/L31

Main circuit power supply input

U/T1 U/T1

V/T2 V/T2

W/T3 W/T3

Drive output

B1 B1

B2 B2

Terminal connections for braking resistor or braking resistor units

+1 +1

DC reactor, DC power supply input (positive)

+2 +2

DC reactor

+3 +3

Braking unit connection (positive)

Negative terminals (for DC power supply and braking units)

r/

1

Cooling fan power supply
C t l

l