(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 49 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Operation when Frequency
Reference is Missing
L4-05 0 L4-05 0
F7 L1000A
L4-05 L4-05
0: Stop
0: Stop
1: Continue operating at
80% speed
1: Continue operating at the
level set to L4-06
Speed Reference at
Reference Loss
L4-06
80 %
L4-06
80 %
─
Door Zone Level
─
─
L4-13*
0.0 %
Sets the door zone speed level.
Number of Auto Restart
Attempts
L5-01
0 times
L5-01
0 times
─
Auto Restart Operation
Selection
L5-02 0 L5-02 0
F7 L1000A
L5-02 L5-02
0: No output
0: No output
1: Outputs during restart
1: Outputs during restart
Fault Reset Interval Time
─
─
L5-04
10.0
s
F
ault Re
sta
rt
UV1 Fault Reset Selection
─
─
L5-06* 0
0: Same as the L5-01 selection.
1: Always automatically reset UV1.
Torque Detection Selection 1
L6-01
0
L6-01
0
F7 L1000A
L6-01, L6-04
L6-01, L6-04
0: Disabled
0: Disabled
1: oL3 detection only active
during speed agree,
operation continues after
detection
1: oL3 detection only active
during speed agree,
operation continues after
detection
2: oL3 detection always
active during run, operation
continues after detection
2: oL3 detection always
active during run, operation
continues after detection
3: oL3 detection only active
during speed agree, output
shuts down on an oL3 fault
3: oL3 detection only active
during speed agree, output
shuts down on an oL3 fault
4: oL3 detection always
active during run, output
shuts down on an oL3 fault
4: oL3 detection always
active during run, output
shuts down on an oL3 fault
5: UL3 detection only active
during speed agree,
operation continues after
detection
5: UL3 detection only active
during speed agree,
operation continues after
detection
6: UL3 detection always
active during run, operation
continues after detection
6: UL3 detection always
active during run, operation
continues after detection
7: UL3 detection only active
during speed agree, output
shuts down on an oL3 fault
7: UL3 detection only active
during speed agree, output
shuts down on an oL3 fault
8: UL3 detection always
active during run, output
shuts down on an oL3 fault
8: UL3 detection always
active during run, output
shuts down on an oL3 fault
Torque Detection Level 1
L6-02
150%
L6-02
150%
─
Torque Detection Time 1
L6-03
0.1 s
L6-03
0.1 s
─
Torque Detection Selection 2
L6-04
0
*
L6-04 0
*
*See the L6-01 description for OL4 and UL4.
Torque Detection Level 2
L6-05
150%
L6-05
150%
─
Over
torque
Detecti
on
Torque Detection Time 2
L6-06
0.1 s
L6-06
0.1 s
─
Forward Torque Limit
L7-01
200%
L7-01
200%
─
Reverse Torque Limit
L7-02
200%
L7-02
200%
─
Torque Limi
t
Forward Regenerative Torque
Limit
L7-03 200% L7-03 200%
─