Braking Resistor
Check to see if the F7 drive currently used has a braking resistor installed.
For F7 drives 3.7 kW and smaller using an ERF-type braking resistor, check the
following:

Verify the braking specifications match the equivalent L1000A replacement unit.
See the Braking Resistor Installation Attachment section of this guide for
specifications. Use only the braking resistor recommended by Yaskawa.

If planning to use the same ERF-type braking resistor installed to F7 in the new
L1000A drive and the cable is too short, replace the cable with a longer one only
if the wire specifications are the same.

Braking units
If braking unit is used, it can simply be transferred over to L1000A as-is.
For braking units 30 kW and below, braking transistor protection should be disabled
in L1000A (L8-55 = 0).

AC or DC Reactor
See if the F7 has an AC or DC reactor that can be reused with L1000A

Option &

Other

Peripherals

Noise Filter
If a noise filter is used, it can simply be used with L1000A as-is.

Thoroughly review the instruction manual included with the new drive.

To request a catalog, product manual, pricing, or shipping dates, please call your local Yaskawa sales office
or representative.

For technical questions, support, or other related information, contact a Yaskawa representative.

Ratings Summary

F7

L1000A

Power
Supply

Model
CIMR-F7U

Rated
Output
Capacity
(HP)

Rated
Output
Current
(A)

Carrier
Frequency
(kHz)

Model
CIMR-LU

Rated
Output
Capacity
(HP)

Rated
Output
Current
(A)

Carrier
Frequency
(kHz)

23P7 5 13.9

2A0018

5 17.5

25P5

7.5 21

2A0025

7.5 25

27P5

10 28

2A0033

10 33

2011

15 41

2A0047

15 47

2015 20 52.9

2A0060

20 60

2018 25 64.8

2A0075

25 75

2022 30 77.5

2A0085

30 85

2030 40 96.8

2A0115

40 115

2037 50 107

2A0145

50 128

2045 60 132.5

2A0180

60 158

2055 75 158.2

2A0215

75 189

2075 100 208.3

2A0283

100 249

2090 125 254.7

8

2A0346 125 304

200 V

3-Phase

2110 150 360

2

2

2A0415 150 365

8