Yaskawa F7 to L1000A User Manual
Page 39
(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 39 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Input Level of External Fault
from Communications Option
Board
F6-02 0 F6-02 0
F7 L1000A
F6-02 F6-02
0: Always detected
0: Always detected
1: Detected during run
1: Detected during run
Stopping Method for External
Fault from Communication
Option Board
F6-03 1 F6-03 1
F7 L1000A
F6-03 F6-03
0: Ramp to stop
0: Ramp to stop
1: Coast to stop
1: Coast to stop
2: Fast Stop
2: Fast Stop
3: Continue operation
3: Continue operation
Trace Sampling from Comm.
Option Board
F6-04
0
F6-04*
2.0 s
*bUS Error Detection Time
Torque Reference/Torque
Limit Selection from
Communications Option
F6-06 0 F6-06 0
0: Switching via comm. network is disabled
F7 L1000A
F6-06 F6-06
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Operation Selection After SI-T
WDT Error
F6-08 1 ─
─
Communicatio
n Op
tion
Ca
rd
Number of SI-T BUS Error
Detection
F6-09 2 ─
─
No corresponding parameter in L1000A.
Digit
al
Input
s
Terminal S3 Function
Selection
H1-01 24 H1-03*
24
(50)
F7 L1000A
H1-01 to H1-06
H1-03 to H1-08
0: 3-wire sequence
─
1: LOCAL/REMOTE
selection
─
2: Option / Drive selection
─
3: Multi-Step Speed
Reference 1
3: Multi-Step Speed
Reference 1
4: Multi-Step Speed
Reference 2
4: Multi-Step Speed
Reference 2
5: Multi-Step Speed
Reference 3
5: Multi-Step Speed
Reference 3
6: Jog freq ref selection
6: Jog freq ref selection
7: Accel/Decel Time
Selection 1
7: Accel/decel time selection
1
8: Baseblock command
(N.O.)
8: Baseblock command
(N.O.)
9: Baseblock command
(N.C.)
9: Baseblock command
(N.C.)
A: Hold accel/decel stop
─
B: Drive overheat alarm
─
C: Multi-func analog input
selection
─
D: Speed control disabled
(V/f w/PG)
─
E: Speed control integral
reset
─