(Header Title) Application Note
Doc#: PL.L1000A.01 Copyright Yaskawa Electric America, Inc.
©2010 www.yaskawa.com September 9, 2010 50 of 57
Subject: Transition Guide
Product: L1000A
Document: PL.L1000A.01
Title: Product Transition Guide – F7 to L1000A
Product Transition Guide – F7 to L1000A
F7
L1000A
Parameter Name
Parameter
Default
Setting
Record
Parameter
Default
Comments:
Gray shading indicates default setting.
Reverse Regenerative Torque
Limit
L7-04 200% L7-04 200%
─
Internal Dynamic Braking
Resistor Protection Selection
(ERF)
L8-01 0 ─
─
No corresponding parameter in L1000A.
Overheat Pre-Alarm Level
L8-02
*
L8-02
*
Determined by drive capacity.
Overheat Pre-Alarm
Operation Selection
L8-03 3 L8-03 3
F7 L1000A
L8-03 L8-03
0: Ramp to stop
0: Ramp to stop
1: Coast to stop
1: Coast to stop
2: Fast Stop
2: Fast Stop
3: Continue operation
3: Continue operation
Input Phase Loss Protection
Selection
L8-05 0 L8-05 1
F7 L1000A
L8-05 L8-05
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Input Phase Loss Detection
Level
─
─
L8-06
*
Determined by drive capacity.
Output Open-Phase
Protection Selection
L8-07 0 L8-07 0
F7 L1000A
L8-07 L8-07
0: Disabled
0: Disabled
1: Enabled (triggered by a
single phase loss)
1: Enabled (triggered by a
single phase loss)
2: Enabled (triggered when
two phases are lost)
2: Enabled (triggered when
two phases are lost)
H
ar
dw
ar
e P
rot
ec
tion
Ground Protection Selection
L8-09
1
L8-09
1
F7 L1000A
L8-09 L8-09
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Cooling Fan Control Selection
L8-10
0
L8-10
0
F7 L1000A
L8-10 L8-10
0: During run only
0: During run only
1: Fan always on
1: Fan always on
─
2: Temp Controlled
Operation
Cooling Fan Control Delay
Time
L8-11
60 s
L8-11
60 s
─
Ambient Temperature Setting
L8-12
45℃
L8-12
40℃
Set the ambient temperature where the drive is being used.
oL2 Characteristics Selection
at Low Speeds
L8-15 1 L8-15 1
F7 L1000A
L8-15 L8-15
0: Disabled
0: Disabled
1: Enabled
1: Enabled
Soft CLA Selection
L8-18
1
─
─
No corresponding parameter in L1000A.
Current Unbalance Detection
─
─
L8-29 1
L1000A
L8-29
0: Disabled
1: Enabled
Internal Cooling Fan Failure
OH1 Detection
L8-32 1 ─
─
F7 L1000A
L8-32
─
0: Alarm detection
1: Fault detection
L1000A does not have an
internal cooling fan